Bard Touchless Plus Unisex Intermittent Vinyl Catheter Kit is a closed system kit that is designed specially for sterile intermittent catheterization. It offers a pre-lubricated catheter to reduce discomfort during insertion. Closed system of Bard Touchless Plus reduces the risk of urinary tract infections and cross-contamination. It provides...
Bard Touchless Plus Unisex Intermittent Vinyl Catheter Kit is a closed system kit that is designed specially for sterile intermittent catheterization. It offers a pre-lubricated catheter to reduce discomfort during insertion. Closed system of Bard Touchless Plus reduces the risk of urinary tract infections and cross-contamination. It provides patient and caregiver an increased level of control and convenience.
What does Bard Touchless Intermittent Catheter Kit include?
(1) Vinyl Intermittent Catheter
(3) PVI swabs
(1 Pair) Latex-free gloves
Underpad
1100cc collection chamber with built in drainage port
Bard Touchless Plus Unisex Catheter Kit Features
Easy to insert, easy to use, easy to remove - the features needed to enhance convenience and usage
Catheter cap has pull ring, especially for people with limited dexterity
Latex-free closed system catheter
Sterile
Single-use
Highlights of Bard Touchless Plus Catheter: 1. Insertion tip correctly positions the catheter in the urethra to help reduce UTIs2. Catheter control guide allows control of catheter insertion with the touch of a finger3. Tapered neck design decreases cuts and scrapes associated with sharp corners4. Catheter cap has pull ring for easy removal5. Pre-lubricated catheter reduces discomfort during insertion6. Large 1100cc collection bag is durable, virtually eliminating the risk of leaks
What to buy with Bard Touchless Plus Catheter Kit
Pivot Self Cath Break-Resistant Acrylic Mirror
Bard Catheter Plug And Cap
Coloplast Self Cath Intermittent Self Catheterization DVD
How to use Unisex Intermittent Catheter?
Male Catheterization With Bard Touchless Plus Catheter:
With one hand, squeeze tabs to keep the insertion tip in place as you use the pull ring to remove the cap. Save cap to close the bag.
Slide the pre-lubricated Bard Touchless Plus Catheter halfway into the insertion tip. You can do this through the bag so your hands do not touch the catheter.
Clean the opening to the urethra and the surrounding area with the provided povidone-iodine swabs
Holding the penis on the sides, advance the insertion tip into the urethra no further than the base of the insertion tip.
Your catheter has a control guide to help stabilize the catheter in the urethra. Grab the guide through the bag with your non-dominant hand. Use your dominant hand to grasp the catheter tube through the bag.
Push the catheter into the urethra. Use a short, repetitive pushing motion. Continue to insert the catheter until it reaches the bladder and urine starts to flow.
Allow urine to flow freely until bladder is empty or bag is filled. Make certain the control guide is elevated at least four inches above lower portion of the bag. Precaution – it is recommended that you hold the collection bag, as the weight of the urine could cause the catheter to separate from the collection bag.
Withdraw the catheter from the urethra, stopping about three times to let any remaining urine drain. Pinch the end of the catheter prior to pulling it out to keep urine from spilling out of the catheter.
Remove the rest of the catheter from the collection bag by pulling it through the insertion tip. Note – the catheter is designed to pass through the insertion tip.
Close the filled collection bag by replacing the cap over the insertion tip. Make sure the cap snaps on securely.
When ready, you can remove the insertion tip to empty the bag. Dispose of the empty bag and packaging in a waste recepticle. Wash your hands with soap and water.
Female Catheterization With Bard Touchless Plus Catheter:
With one hand, squeeze tabs to keep the insertion tip in place as you use the pull ring to remove cap. Save cap to close the bag.
Slide the pre-lubricated catheter halfway into the insertion tip. You can do this through the bag so your hands do not touch the catheter.
Clean the opening to the urethra and surrounding area by holding the outer labia apart and cleaning with the provided povidone-iodine swabs. Wipe the urethra opening to the bladder, from front to back to avoid fecal contamination.
Spread the inner labia and advance the insertion tip into the urethra no further than the base of the insertion tip. Release the inner labia.
Your catheter has a control guide to help stabilize the catheter in the urethra. Grasp that through the bag with your non-dominant hand. Use your dominant hand to grasp the catheter tube through the bag.
Push the catheter into the urethra, aiming upwards towards the navel. Use a short, repetitive pushing motion. Continue to insert the catheter until it reaches the bladder and urine starts to flow.
Allow urine to flow freely until bladder is empty or bag is filled. Make certain the control guide is elevated at least four inches above lower portion of the bag. Precaution – it is recommended that you hold the collection bag, as the weight of the urine could cause the catheter to separate from the collection bag. 8. Withdraw the catheter from the urethra, stopping about three times to let any remaining urine drain. Pinch the end of the catheter prior to pulling it out to keep urine from spilling out of the catheter.
Remove the rest of the catheter from the collection bag by pulling it through the insertion tip. Note – the catheter is designed to pass through the insertion tip.
Close the filled collection bag by replacing the cap over the insertion tip. Make sure the cap snaps on securely.